Power keeps tripping? Start here.

When your power keeps tripping, something on that circuit is overloaded or leaking current. A circuit breaker trips when a circuit is overloaded or shorted, and a safety switch trips when current leaks to earth. Which one trips, and when, tells you where to look. This guide helps you work out which kind of tripping you have.

Quick facts

  • A safety switch trips when current leaks to earth. Home safety switches trip at 30 milliamps.
  • A circuit breaker trips when a circuit is overloaded or shorted.
  • Tripping at the same time each night usually points to something on a timer, like a pool pump or hot water. If it’s the hot water, see hot water system fault finding.
  • Tripping in wet weather usually points to water in outdoor power points, lights or cables.
  • If it trips again with everything unplugged, the fault is in the fixed wiring. That needs a licensed electrician.

5.0★★★★★from 56 Google reviews

  • Licensed, QLD licence 90386
  • Tripping faults traced across the southside
  • Price agreed before we start
Electrical fault finding in Annerley, Brisbane: isolating a switchboard to test a tripping circuit

Isolating a switchboard to test a tripping circuit in Annerley.

“

Had these guys come round to sort some new lighting and power points. Super easy to deal with, showed up on time, no fuss, and cleaned up after. Proper quality job, would 100% get them back again.

★★★★★ Mark J., Google review

Licensed and insured

QLD electrical contractor licence 90386.

Price agreed first

You get the full price in the quote before we start.

Test first, then fix

We find the real cause before anything gets replaced.

First step

Which switch is tripping?

Open the switchboard door and look for the switch that has dropped. There are three kinds, and each one trips for a different reason. Not sure which is which? Take a photo of the board with the door open and send it to us.

A circuit breaker

A small switch for one circuit. It trips when that circuit is overloaded or has a short circuit, so think about what was running when it went off.

A safety switch (RCD)

Usually the one with a test button. It trips when current leaks to earth, often from a faulty appliance, water in a fitting or tired wiring. Read why a safety switch keeps tripping.

The main switch

If the whole house drops out at the main switch, stop there. Leave it off and give us a call.

Burning smell, sparks or a hot power point?

Leave the circuit off and call us. If there is smoke or fire, get out and call 000.

Patterns

When does your power keep tripping?

When it trips tells you more than anything else. Find your pattern below, then read the page that covers it.

When it tripsWhat it often meansWhere to read more
Every time it rainsWater has got into an outdoor light, power point or fitting, so current leaks to earth.why a safety switch keeps tripping, and the Electrical Safety Office guide to safety switches
When the hot water heatsThe element, thermostat or wiring on the hot water circuit.hot water system tripping the safety switch
When you switch on one applianceThat appliance is faulty, or the circuit is carrying too much.Try the quick test further down this page
Straight away, or with everything unpluggedA fault in the fixed wiring.electrical fault finding in Brisbane
Nothing trips, but a power point is deadThat’s not a trip at all.power point not working but the breaker has not tripped

Recent power tripping jobs

These come from our job records on Brisbane’s southside. Suburb, problem and fix only.

  • Runcorn: the RCD kept tripping on the power circuit, but the wiring was fine. We traced it to a faulty appliance, most likely the washing machine, so no wiring work was needed.
  • Eight Mile Plains: the lights kept tripping. We traced the earth fault to a faulty ceiling fan in the main bedroom, then replaced it.
  • Annerley: a power circuit kept tripping. We found water in several power points, dried and secured them, then retested the circuit.
Water damaged power point that kept tripping the safety switch, Annerley, Brisbane
Annerley Fixed Water in the power points. A power circuit kept tripping. We found water in several power points, dried and secured them, then retested the circuit.

Before you call

What can I safely check when the power keeps tripping?

01

Warn the household

Tell everyone the power is about to go off on that circuit.

02

Unplug everything

Unplug every appliance on the dead circuit. This is the only DIY step we suggest.

03

Reset the switch

Push the tripped switch back on. If it won’t stay on with nothing plugged in, stop there and call us.

04

Plug back in, one at a time

Plug things back in one by one. The one that trips it is the culprit.

Call us when

Power keeps tripping: when do I need an electrician?

Call us if it trips with everything unplugged, trips again once you plug things back in, or you can’t find the cause. Finding it is a job for test equipment, not guessing. We test the circuit, find the fault and give you the repair price before we fix anything. Costs and how it works are on our electrical fault finding page. If the board itself is old and full, switchboard upgrades may be the real fix.

At the switchboard

Take a photo of the board with the door open. It shows us which switch tripped and roughly how old the board is.

Note down

  • Which switch tripped
  • Whether it trips straight away or later
  • What was running when it went off

When to stop

Don’t keep resetting a switch that keeps tripping. Forcing it on can be dangerous. Leave it off and call us.

Stop if

  • It trips with nothing plugged in
  • You can smell burning
  • A power point or switch is hot, warm or marked
  • The switch won’t stay on
M-Tech electricians in blue branded shirts beside their work van in Brisbane

Why M-Tech

Why Brisbane homeowners book M-Tech.

We’re a small Brisbane team, so the electrician who turns up actually cares how the job ends. No call centre, no jargon, no upsell.

  • Southside local. We trace tripping faults across Brisbane’s southside, from Coorparoo to Slacks Creek.
  • Price first. You approve one clear price before we start, with no add-ons on the day.
  • Careful in older homes. We protect floors and furniture, then clean up before we go.
  • Tested every time. We test every repair and install before we leave.
  • Licensed and insured. We hold QLD electrical contractor licence 90386.

Google reviews

Rated 5.0 by 56 Brisbane customers

Where we work

Help with power tripping across Brisbane’s southside

M-Tech Electrical Solutions QLD is a licensed Brisbane electrician based in Norman Park 4170, serving Brisbane’s southside and inner east, including Coorparoo, Camp Hill, Carina, Morningside and Bulimba, and travelling across South East Queensland when a job needs it. Hours are Monday to Friday, 7am to 5pm. Something urgent? See our emergency electrician page, or check all our service areas.

Inner east and riverside

Most days start in the inner east, around Norman Park, Bulimba and Cannon Hill.

Inner south

Coorparoo, Camp Hill and Carindale are regular stops between jobs, and so are Holland Park and Annerley.

South and south-east

We also head south through Mount Gravatt and Rochedale to Springwood.

Good to know

Power keeps tripping: FAQs

Something specific? Call 1800 549 545 and ask an electrician.

Something on that circuit is overloaded or leaking current. A circuit breaker trips on overload or a short circuit. A safety switch trips on a leak to earth. Which one trips, and when, tells you the cause. Unplug everything on the circuit and plug back in one at a time.

It can be. A switch that trips is doing its job, but the cause is still there. If there is a burning smell, a hot power point or sparks, leave it off and call us. If there is smoke or fire, call 000.

A circuit breaker protects the wiring from overload and short circuits. A safety switch protects people by cutting power fast when current leaks to earth. An RCBO does both jobs in one device. They trip for different reasons, so which one trips matters.

Water has probably got into an outdoor light, a power point or a fitting. That lets current leak to earth, and the safety switch trips. Leave the circuit off and call us. We find the wet fitting, repair it and retest the circuit.

Either the appliance is faulty, or that circuit is carrying too much. Plug the appliance into a different circuit. If it trips there too, the appliance is the problem. If not, the first circuit is overloaded or has a fault.

No. A switch that keeps tripping is telling you something is wrong. Resetting it again and again does not fix the cause, and forcing it on can be dangerous. Leave it off if it trips straight away, and call us.

Yes. Old boards can have worn breakers, loose connections or too many circuits on one device. If the board is also full or still has ceramic fuses, a switchboard upgrade may be the fix. We inspect the board first, then tell you.

Free advice

Power keeps tripping? Tell us what’s happening.

Leave a few quick details and we’ll call to talk it through and book a time. A photo of the problem also helps. Monday to Friday.

What happens next

  • We call you back, usually the same working day
  • Then we confirm what’s needed and book a time
  • You approve the price before we start

“Excellent service from M-Tech Electrical Solutions! MJ attended and quickly diagnosed the issue with our safety switch.” ★★★★★ Michael B., Google review

This doesn’t lock in a booking. We’ll call to confirm a time first.

5.0★★★★★ from 56 Google reviews

Licensed and insured, QLD electrical contractor licence 90386

Scroll to Top