M-Tech Electrical Solutions QLD

Smoke alarm types · Updated November 2026

Smoke alarm types in Queensland. Photoelectric, interconnected, hardwired or battery.

Smoke alarm types in Queensland differ in two ways: how they sense smoke, and how they are powered. Here is each type in plain English, and how to tell what is on your ceiling now. For what the 2027 rules ask for, see our QLD smoke alarm laws for 2027 guide.

5.0★★★★★from 56 Google reviews

  • Licensed, QLD licence 90386
  • Smoke alarms fitted across the southside
  • Price agreed before we start
Interconnected photoelectric smoke alarm on a living area ceiling in a Carindale home

Carindale: an interconnected photoelectric smoke alarm on a living area ceiling.

“

Had these guys come round to sort some new lighting and power points. Super easy to deal with, showed up on time, no fuss, and cleaned up after. Proper quality job, would 100% get them back again.

★★★★★ Mark J., Google review

Licensed and insured

QLD electrical contractor licence 90386.

Price agreed first

You get the full price in the quote before we start.

Test first, then fix

We find the real cause before anything gets replaced.

How they sense smoke

What is the difference between photoelectric and ionisation smoke alarms?

There are two common smoke alarm types in Queensland homes, and they sense smoke in different ways.

Photoelectric

A light beam inside the alarm. Smoke scatters the light and sets it off. Good at picking up smouldering fires, like bedding, a hot appliance or overheating wiring. Less likely to go off from cooking.

Ionisation

A tiny radioactive source inside. Reacts best to fast, flaming fires. Goes off more from toast and steam, which is why people pull the battery out.

What we fit

We fit photoelectric alarms. Our QLD smoke alarm laws for 2027 guide covers what the rules ask for, and the Queensland Fire Department is the official source.

Chirping instead of sounding? See smoke alarm beeping or chirping.

Burning smell, sparks or a hot power point?

Leave the circuit off and call us. If there is smoke or fire, get out and call 000.

Check your ceiling

How do I tell which smoke alarm type I have?

Take the cover off only if it twists off by hand, and never touch a hardwired alarm’s wiring. Look at the label on the back or the side.

What the label tells you

  • It says photoelectric or photo. Good.
  • It says ionisation or ion, or has a radioactive warning symbol. We swap it for photoelectric.
  • No label, or a date stamp more than 10 years old. Replace it.
  • A green or orange light and a cable into the ceiling means it is hardwired. Leave the wiring alone and ask us.

Not sure?

  • Send us a photo of each alarm and its label.
  • We tell you what you have and what it needs.
  • Do not pry open an old alarm.
  • Ask the maker or your council how to get rid of an old one.

How they are powered

What are the power options for smoke alarms?

01

Hardwired, 240 volt

Wired into your house power with a backup battery, so it keeps working in a blackout. Fitted by a licensed electrician.

02

10-year sealed battery

A battery you can’t remove, so it can’t be taken out and forgotten. Lasts about as long as the alarm. No cable needed.

03

Replaceable battery

The old 9 volt or AA style. The one people pull out and forget. Our laws guide covers which power options the rules list.

04

Interconnected

When one alarm detects smoke, every alarm in the house sounds. Linked by cable, by radio or a mix. See interconnected smoke alarms: wired or wireless.

Which mix

Which smoke alarm types suit which house?

Most homes end up with one of these. Not sure? Send us a photo of each alarm and the label.

Already hardwired

Swap for hardwired photoelectric alarms with radio linking, then add any missing bedroom alarms. Usually the quickest.

Good fit for

  • Homes with alarms already wired in
  • Single storey homes with roof access
  • Two storeys: hardwired in the hallways, 10-year battery in bedrooms

Battery alarms only

No easy roof access? 10-year battery photoelectric alarms linked by radio. No new cabling.

Good fit for

  • Homes with no roof space to work in
  • Units and townhouses
  • Adding a bedroom alarm without new cable

Where and who

Where do the alarms go?

Our QLD smoke alarm laws for 2027 guide has the full detail on where alarms go. We don’t restate the rules here.

While we are up there, we can check other things too. Old wiring often shows up with an old switchboard, see switchboard upgrades. For the rest of the house, see our residential electrician page.

Who can fit smoke alarms?

A licensed electrician fits hardwired alarms. For sealed battery alarms, the Queensland Fire Department smoke alarm FAQ is the place to check what applies.

M-Tech electricians in blue branded shirts beside their work van in Brisbane

Why M-Tech

Why Brisbane homeowners book M-Tech.

We’re a small Brisbane team, so the electrician who turns up actually cares how the job ends. No call centre, no jargon, no upsell.

  • Southside local. We fit smoke alarms across Brisbane’s southside, from Coorparoo to Slacks Creek.
  • Price first. You approve one clear price before we start, with no add-ons on the day.
  • Careful in older homes. We protect floors and furniture, then clean up before we go.
  • Tested every time. We test every repair and install before we leave.
  • Licensed and insured. We hold QLD electrical contractor licence 90386.

Google reviews

Rated 5.0 by 56 Brisbane customers

Where we work

Smoke alarm help across Brisbane’s southside

M-Tech Electrical Solutions QLD is a licensed Brisbane electrician based in Norman Park 4170, serving Brisbane’s southside and inner east, including Coorparoo, Camp Hill, Carina, Morningside and Bulimba, and travelling across South East Queensland when a job needs it. We are in Norman Park, Camp Hill, Coorparoo, Holland Park and Annerley most weeks, Monday to Friday, 7am to 5pm. Something urgent? See our emergency electrician page, or check all our service areas.

Inner east and riverside

Most days start in the inner east. We’re the local Norman Park electrician, and we’re often in Bulimba and Morningside.

Inner south

Coorparoo, Camp Hill and Holland Park are regular stops. Need an electrician in Camp Hill or an electrician in Holland Park? Same team, and we’re the Carindale electrician too.

South and south-east

We also head south through Annerley, Mount Gravatt and Rochedale to Springwood. Ask for our electrician in Annerley.

Good to know

Smoke alarm types: FAQs

Something specific? Call 1800 549 545 and ask an electrician.

Photoelectric alarms sense smoke with a light beam and respond well to smouldering fires. Ionisation alarms use a tiny radioactive source and respond best to flaming fires, but go off more from cooking. We fit photoelectric alarms, and our QLD smoke alarm laws guide covers the 2027 rules.

Read the label on the back or side. It says photoelectric or photo. If it says ionisation or ion, or has no label, or is more than 10 years old, replace it. If you can’t read it, send us a photo.

Not if it is a photoelectric alarm that is linked to the others and still in date. When the 10 years is up, the whole alarm is replaced. Our QLD smoke alarm laws guide covers which power options the rules list.

Yes, as long as they are all photoelectric and linked together so they sound as one. A common setup is hardwired in the hallways and 10-year battery alarms in the bedrooms, all linked by radio.

About 10 years from the date of manufacture, which is printed on the alarm. After that the sensor wears out, so replace the alarm even if it still beeps when tested.

Every alarm is linked, so when one detects smoke, all of them sound at once. They can be linked by cable, by radio or both. That way you hear a fire in a back bedroom from the other end of the house.

Free advice

Not sure what’s on your ceiling? Ask us.

Leave a few quick details and we’ll call back. A photo of each alarm and its label helps. Monday to Friday.

What happens next

  • We call you back, usually the same working day
  • We talk through what you’ve noticed
  • Any work gets a free quote first

“Excellent service from M-Tech Electrical Solutions! MJ attended and quickly diagnosed the issue with our safety switch.” ★★★★★ Michael B., Google review

This doesn’t lock in a booking. We’ll call to confirm a time first.

5.0★★★★★ from 56 Google reviews

Licensed and insured, QLD electrical contractor licence 90386

Scroll to Top